A granny flat (secondary dwelling) can be approved as complying development in NSW under State Environmental Planning Policy (Housing) 2021 when the lot is in a residential zone other than R5, is at least 450 square metres (not counting the access laneway of a battle-axe lot), meets the Schedule 1 frontage of 12 metres for lots of 450 to 900 square metres, 15 metres up to 1,500 and 18 metres above that, and every other Schedule 1 standard. The granny flat itself is generally limited to 60 square metres of floor area, or more if the LEP allows. The Housing Code does not apply to secondary dwellings. It applies to the main house, so a project combining a new house and a granny flat has to satisfy both. Lots under 450 square metres, heritage and other excluded land, and designs that miss a standard need a development application instead.
Key takeaways
- Complying development for a granny flat generally needs a lot of at least 450 square metres in a residential zone other than R5, excluding any battle-axe access handle.
- Schedule 1 of the Housing SEPP requires a primary road frontage of 12 metres (lots 450 to 900 square metres), 15 metres (up to 1,500) or 18 metres (above 1,500), or for a battle-axe lot a 3 metre laneway and a lot at least 12 by 12 metres.
- A secondary dwelling is capped at 60 square metres unless the LEP allows a larger area.
- The Housing Code does not apply to secondary dwellings, but an approved granny flat does not count towards the Housing Code’s one-dwelling-house limit.
- Land exclusions such as heritage, flood and bushfire limits apply to granny flats as they do to houses.
Who this is for: investors and home owners in Western Sydney, the Central Coast and regional NSW thinking about adding a granny flat behind an existing house, or building a new house and granny flat together, who want to know quickly whether a certifier can approve it.
Does my lot qualify for a complying granny flat?
| Test | Standard | Source |
|---|---|---|
| Zone | Residential zone other than R5 (and the LEP permits secondary dwellings) | Housing SEPP |
| Lot size | At least 450 sqm, excluding a battle-axe access handle | Housing SEPP |
| Frontage, lots 450 to 900 sqm | 12 m | Schedule 1 |
| Frontage, lots over 900 to 1,500 sqm | 15 m | Schedule 1 |
| Frontage, lots over 1,500 sqm | 18 m | Schedule 1 |
| Battle-axe lot | Access laneway at least 3 m wide; lot at least 12 m by 12 m excluding the laneway | Schedule 1 |
| Floor area | Up to 60 sqm (or the LEP’s larger figure) | Housing SEPP Chapter 3 |
Schedule 1 also sets site coverage, setback, height, privacy and other standards for the granny flat, which the design must meet. The common mistake is to look only at the 450 square metre figure. A 460 square metre lot with an 11 metre frontage fails the frontage test.
House plus granny flat: which rules apply?
The Department’s Guide to Complying Development explains that the Housing Code does not apply to secondary dwellings, and that a secondary dwelling with its own consent or complying development certificate does not count towards the Housing Code limit of one dwelling house per lot. In practice:
- the new house is tested against the Housing Code (floor area under clause 3.9, landscaped area, setbacks, height);
- the granny flat is tested against the Housing SEPP and Schedule 1;
- both have to fit on the lot together, which in practice means the landscaped area, open space and access for both dwellings need to be resolved in one site plan.
Our CDC calculator shows the house figures and the granny flat lot and frontage tests side by side when you choose “New house plus a granny flat”.
Worked examples
| Lot | Area | Frontage needed | Indicative outcome |
|---|---|---|---|
| 12 m x 36 m | 432 sqm | n/a | Under 450 sqm: not complying; DA possible |
| 12.5 m x 40 m | 500 sqm | 12 m | Lot and frontage tests met; design standards to check |
| 15.24 m x 61 m | 929 sqm | 15 m | Lot and frontage tests met |
| Battle-axe, 650 sqm with 80 sqm handle | 570 sqm counted | 3 m laneway | Met if laneway is 3 m and the lot is 12 m by 12 m |
The steps to a granny flat approval
- Check zone, heritage, flood and bushfire on the section 10.7 planning certificate.
- Confirm lot area (less any handle) and frontage from the deposited plan.
- Run the lot through our CDC calculator.
- Locate sewer and stormwater pipes and easements before placing the granny flat.
- Design to Schedule 1 and obtain a CDC from a certifier, or lodge a DA if a standard cannot be met.
- Obtain Sydney Water building plan approval and a BASIX certificate.
Definitions
- Secondary dwelling
- A self-contained dwelling on the same lot as a principal dwelling, commonly called a granny flat, regulated by Chapter 3 of the Housing SEPP.
- Schedule 1 (Housing SEPP)
- The complying development standards for secondary dwellings, including lot, frontage, setback, height and site coverage requirements.
- Principal dwelling
- The main house on the lot.
- Battle-axe lot
- A lot reached by a narrow access laneway; the laneway is excluded from lot area for these tests.
Frequently asked questions
What is the minimum lot size for a granny flat CDC in NSW?
Generally 450 square metres, not counting the access laneway of a battle-axe lot, in a residential zone other than R5.
How wide does my lot need to be for a granny flat CDC?
12 metres for lots of 450 to 900 square metres, 15 metres for lots up to 1,500 and 18 metres above that, under Schedule 1 of the Housing SEPP.
Can I build a granny flat on a 400 sqm lot?
Not as complying development. A development application may still be possible, depending on the LEP and DCP.
How big can a granny flat be in NSW?
Generally 60 square metres, unless the LEP permits a larger area for secondary dwellings.
We plan granny flats every week through our granny flat planning service, and prepare DAs where the complying route is not available. Start with the free CDC calculator, then request a fee proposal for a site review.
Sources and references
- State Environmental Planning Policy (Housing) 2021, Chapter 3 Part 1 Secondary dwellings and Schedule 1, accessed October 2026
- NSW Department of Planning and Environment, Guide to Complying Development (August 2023), Housing Code: secondary dwellings note, accessed October 2026
- State Environmental Planning Policy (Exempt and Complying Development Codes) 2008, Part 1 land exclusions, accessed October 2026
Information disclaimer. This article is general planning information prepared by the URBA Planning Team and is current at the date of publication. It is not planning, legal or financial advice for any specific property. Planning instruments, development control plans, state policies and the National Construction Code are amended regularly and councils interpret them differently; the controls quoted here should be confirmed against the versions in force at the date of lodgement and against the consent authority’s current requirements. Reliance on this article is at the reader’s own risk. URBA Planning, a division of Contrive Consultants Pty Ltd, accepts no liability for loss arising from its use. For advice on a specific site, contact URBA for a fee proposal.